À§·Î

±â¼úÀÚ·á

±â¼úÀÚ·á

ƼŸ´½ÀÇ ¿ëµµ
ƼŸ´½ÀÇ ¼ººÐ
ƼŸ´½ ³»½Ä¼º ±â¼úÀÚ·á

CS Center

032-812-7974
open 09:00 - 18:00

ƼŸ´½ ³»½Ä¼º ±â¼úÀÚ·á

Organic Acids, Organic Compounds in General (À¯±â»ê, À¯±âÈ­ÇÕ¹°)

ºÎ½Ä¸ÅÁú¼ººÐ¿Âµµ(¡É)³»½Ä¼º
¼ø¼öƼŸ´½Áö¸£ÄÚ´½STS 316ÇϽºÅÚ·ÎÀÌ C
ÃÊ»ê
(CH3COOG)
99%25AAAA
BoilingAABA
30% (vapor)BoilingAA
65%30AA
¼ö»ê
((COOH)2)
10%60BAB
BoilingCACB
50%30CACB
˂Ȑ
(HCOOH)
9% (water solution)50BABA
90% (permebility)100AACB
25%100CACB
BoilingCACB
50%30AABA
BoilingCACB
À¯»ê
(CH3CH(OH)COH)
50%100AAB
BoilingAAC
100%BoilingAA
»ç¿°È­Åº¼Ò
(CCl4)
99%BoilingAAB
100%BoilingAAB
º¥Á¨
(C6H6)
100%80AA
Æä³î
(C6H5OH)
Æ÷È­¿ë¾×30AAAB
Note : With respect to the designation of corrosion resistance qualities.
  • A

    The corrosion rate is under approximately 0.1mm/year and is almost completely corrosion resistant.
    ºÎ½ÄÀ² ¾à 0.1m/yearÀÌÇÏ À̸é, ¿Ïº®ÇÑ ³»½Ä¼ºÀ» °¡Áü

  • B

    The corrosion rate is approximately 0.1-1mm/year and may be used in cases where slight traces of corrosion are permitted.
    ºÎ½ÄÀ² ¾à 0.1-1m/yearÀÌÇÏ À̸é, °æ¹ÌÇÑ ºÎ½ÄÀÌ Çã¶ôÇÏ´Â ºÎºÐ¿¡ »ç¿ë °¡´É

  • C

    The corrosion rate is in excess of approximately 1mm/year and is not suitable as an anti-corrosion material.
    ºÎ½ÄÀ² ¾à 1m/yearÀÌÇÏ À̸é, ¹ÝºÎ½Ä¼º ¹°Áú·Î ÀûÇÕÇÏÁö ¾ÊÀ½.